Vic Bobbin Style 1 Stanley Meyer

Winding the VIC 

all the VIC s are based on the same concept.frequency switch to transformer  transformer, to inductors, to cell

Vic Winding for 11 clell tubes

 

VIC:- primary - 200 turns / 24 gauge- secondary - 600 turns / 36 gauge- resonant chokes - 2 x 100 turns / 24 gauge

(in accordance with Stan Meyer`s US Patent 4,936,961)

 

MAx Millers Forum

The primary is a single coil 500 or 600 turns of 30ga

secondary is around 3000 turns 30 ga

c1 is around 3000 turns of 30 ga

c2 is around 2800 turns of 30ga

all in the same direction in relation to the core shape the feedback was center tapped......looks to be

 

NOtes 

the transformers stan made were 29GA and 36Ga secondaries. 
it depends on what you wish to try. 
i would suggest trying exactly what stan made. the square vic was all 29 GA 29-30GA

The VIC Coils

  • Transformer Primary Yellow 

  • Transformer Seconday Blue

  • Chokes Red 

  • Pick Up Feed Back Green

 

edit  below  chokes cw and secondary & primary ccw

30 ga wire for the bobbins on the C coresdon made a small error , he said 29 ga, 29 ga is not correct to fill the bobbin as the picture shows. 30 ga must be correct

The 10-11 cell is not made to be adjustable. It is made to be stable, Meaning, every cell machined to the same size so each and everyone will have the same capacitance. Like max said that is the reason their is one cell that is not hooked up. That is how you adjust the capacitance, by hooking up one through what ever to get the capacitance you need. As in the video you can see by adding more capacitance you can reduce your inductance. If you are using a varic to drive your cells then you know your drive frequency is 120Hz once it goes through the bridge rect. Then you need a resonate frequency for the inductor and capacitors that will match your drive frequency. The permeability of the core is something we all have been playing with. My best luck so far is some were around 2000 perm. The higher perm. the less winds you need which will give you the same inductance as a low per. with more turns if you follow me. Right now I am useing a low perm on the primary and a high perm on my chokes. It is working out well for me right now. You will have to experiment with your setup. That is way it is so critical that everyone have the same setup. Because what works for my setup want work on yours.

 

NOTE FROM TONY WOODSIDE

 

Well as Stan states in his papers that the chokes act as a frequency doubler, then you cannot use the basic series LC formula 1/(2pi* sqrt(LC)) to find the Resonant Frequency. So i came up with a formula to find this resonant frequency. Here is an example:if you pulse the Primary @ 5khz, the Secondary will also pulse @ 5khz, the chokes will have 5khz going in but will have 10khz coming out so that the Capacitor will be hit with a 10khz frequency!!!So for a normal LC non-doubling circuit you would have the following:Primary pulsed @ 5khz the LC resonant frequency for a setup with the Sec+L1+L2= 9H and C= 1.6nF Resonant Freq. = 1327 HzNow this same set up as a LC Frequency Doubling circuit would give the following resonant frequency:Primary pulsed @ 5khz the Resonant Frequency = 938 HzSo as you can see we have a lower Resonant Frequency from the same circuit and the only difference one is configured as a frequency doubler. This has to be accounted for in Stan's setup!!!!

 

 

NOTE FROM DON

The blocking diode goes to the positive choke and always goes to the positive tube (outside tube).The negative isolated ground wasn't hooked to any ground either.In Stans circuit,there is a 5 amp 1000 volt diode between the TIP120 and the primary coil.

Stan also put a diode across the inputs to the primary.From ground to positive.

 

NOte From MAx 

 

ordered Magnet Wire 30 AWG Gauge Enameled Copper 200C 5lb 15660ft Magnetic Coil Winding 
you can look at the ohm reading of dons measurements, then look up the ohms per 1000ft of wire. a little math will tell you how many feet is on the bobbin. i posted how many turns i came up with somewhere.. 
ohms value can change slightly, due to exact size of wire and tension stretching it. the wire size can vary slightly due to tolerance and manufacturer. 

the coating on the wire can change the inductance sllghtly, thickness vary as i said about the wire 

from memery, 500 turns on primary, 3000 secondary, inductors are 3000 and one was 2800..........roughly 
i will find my measurements  just remember different wire from different companies can vary in ohms and even you put too much tension on it can change the readings. 
i took and wound the wire to read the same ohms, then took note of everything else.I believe the turn count will be greatly effected by this. more then 10 turns. I am in favor of 500 turns to the primary and 3000 turns for the secondary.... inductors changed respectively. 

3000 turns is a lot, the inductance will change greatly with the turn count. and odd number of turns effect things greatly as well 

I hold to my theory that 2000 perm it is for the inductors 
and my theory is the primary and secondary needs to be an even number, based on transformer theory. however there is no known theory for the inductors. I say theory because there is no car running on water at this time. when we are finished and the car is running, we call call each theory a fact. 

all electric theory are called theory because , new theory comes along all the time. and science simply can not explain everythingtalked to don last night on the phone.............he says 29 gage is what he measured. 
however different manufactures make a minor difference in wire size. i still like the 30 ga 
i wound 29 and 30............30 ga looked the best

Vic 1 Ferrite  Core

 

Backup and yes we have 4 to 5 backups you should immediately do same download it now be warned 

Stanley Meyer Bobbin VIC Cores

Different perm of ferrite cores tested with a ramping wave pulse output HIgher Perm Higher Voltage

Custom Cores

Note =VIC made from Mn-Zn 10mmx100mm ferrite rods provides more accurate inductance's with similar


Sourced Ebay category link here 

These cores have a lower AL value than all the others I've tried plus a much larger winding window. So, these cores give me much closer inductance values  for the same amount of turns and resistance than Stan   had in his VIC.

Backup and yes we have 4 to 5 backups you should immediately do same download it now be warned 

Stanley Meyer Bobbin VIC Cores

Dan thanks for posting this.  These look like the rods I purchased just longer.  I was not sure how I was going to build mounts for these reason I decided to start with flat pieces.  He says he is not using gap.  It is my understanding that gap serves 2 purposes 1) lowers AL value and 2) is used to do coarse adjustment of the phase offset of signal.  Ronny Walker talked about that in his thread comment about gap by him for example
Re: "Understanding How Stan Meyers Fuel Cell Works"
« Reply #606, on November 11th, 2016, 11:33 AM »Last edited on November 11th, 2016, 11:35 AM
Getting back to Stan's Vic, can everyone see how the gap between the cores controls the coupling from the Primary to the Secondary which in return controls and fine tunes the voltage in the secondary and L1. And if you follow through with this to the positive plate, it also fine tunes the charge on that plate.

It would be easy to create a gap with setup by using two shorter rods on sides with coils instead of one long rod.

I am BradK on youtube, I made that video Dan posted. I have been doing tests with and without gaps in the cores. Mostly what I'm trying to find is an off the shelf core that will give me the right balance. What I have found is that most off the shelf ferrite cores have AL values that are much too high, honestly I'd be surprised if any of them worked. So far I think the rods (or the flat bar your using) have the best chance of working.

The problem I'm having-You can gap any core and get the right inductance values, but the gap creates an invisible inductance and if it's too high it will take all the voltage. I posted a video on this a while back on how the leakage inductance is so high my tests showed I needed a load impedance of greater than 1M ohm just to get the voltage from the turns ratio across the load. I thought by getting current flowing the gas bubbles at electrodes would restrict current enough to allow the process to begin but my research since then says otherwise.

Also- Do you have a 3D printer?
I bought one last August for $123 with shipping. Definitely worth it. After fixing a few problems on it it's worked great ever since. I use Tinkercad (free online 3d modeling program) to design my bobbins etc. A 3D printer is the most useful thing I have bought for SM research so far.

Vic Core Options  that work 

Stans Original Compared

Vic 1 PLastic Bobbin

3d Printer Files  Section

Proven Working Alternative

Backup and yes we have 4 to 5 backups you should immediately do same download it now be warned 

Stanley Meyer Bobbin VIC Cores

Note from Brad

Simplifying the VIC circuit and doing the math to see what it shows us. We know the VIC is a step up transformer, and as such it has to draw the same (close to the same) amount of power on both the primary and secondary sides of the circuit in order to work properly. First problem, how do we calculate the turns ratio when we only have the resistance, wire size, and bobbin dimensions of each coil?

 

Second, if all three coils (secondary, L1 choke, and L2 choke) are on the same core does each coil act as a secondary coil? Third, if both the secondary and primary coils used the same size wire and their bobbins had the same dimensions can we use the resistive values of each to determine the turns ratio?

 

Following the math shows us a little bit more about how the VIC works. It shows us that the secondary coil is the only coil in the secondary circuit has an induced voltage, and that the chokes only act as chokes-not additional secondary coils. It shows us that the turns ratio is about 1:4.56 and that peak current through the secondary coil is about 250mA. Also, the spreadsheet shows a maximum secondary current of 255mA required to produce 20kV across the load at 10kHz.

 

*Keep in mind we are assuming a pulsed DC signal with a pulse long enough to get full current flowing through the primary and secondary circuits. In reality it is difficult to get high currents flowing through the circuit because the rate of rise of the current is limited by the L/R time constants of the circuit. In all my testing the only thing that has caused the circuit to pull more current is when I increased the duty cycle of the resonant and gate pulses and added lower amplitude pulsing during the gate time.

the 
the vic transformer 
1200 perm is right on the money 
1600 perm is on the money with a piece of tape on one side to make a gap. 
2000 perm however is closer to the frequency of 5khz 

i would say the inductor needs to be 1 H for 10 cells in series 
really i am not sure of the inductance needed for one cell 

i have tried the isolated ground to ground.....as well as grounded the neg of the cell......... nothing 

as long as the amperage is low..........should be no harm done in the connection 

the injector would have been grounded to the engine block

Stanley A Meyer Bobbins  VIC

Feed Back Coil -Pick Up Coil

Used to Find and Lock Resonance The pickup coil is used for resonate feedback to the scanning and PLL circuit that senses resonance. More or less senses the highest peek voltages and locks onto that frequency.They will be no amp draw from your power source at resonance the transistor will run cold not even warm. This plainly states no amp flow in the cell. Nothing but voltage. 

Well according to Don's drawing the center tap is start of the wind and logically you would want a very small signal going to the phase lock loop circuitry.

 

Thereby giving you small deviations on the 5K hertz center frequency. If you read the international patent Stan talks about impurities knocking the cavity out of resonance. Impurities which would change the dielectric value of the water molecule. See attached photo for clarification.

 

Again none of this would have been possible if it weren't for Don Gable documentation of the Stanley Meyer Estate. See Don's attached drawing for clarification.

 

so 2 coils center tap is the startsss which one is longer then the connected side or the not connected side The one that gives you the most bubbles using 10 Vic's

 

need to figure out 10 center tap non-inductive feedback coil need to be tuned in. 
 

This shows the amp draw from your battery or power supply at resonance. He states at startup the amp draw will be 25 m/amp and at resonance it will be 1-2 m/amp. So if your drawing more than 25 m/amp at startup would you not think you have something not designed properly on the primary side? I would think so.  the chokes are part of the turn ratio of the secondary. Which means that the secondary turn and the choke turn are all added together for the ratio on the secondary side of the transformer. What he left out was the word (and) in between secondary charging chokes.

I agree with that but and measures taken from cell ,what says that on primary winding may be different input 
and according to my knowledge it is easier to tune cells with stronger power -Of course that can slowly reduce 
and pickup coil if so then it does not allow drop of magnetic field or opposite 
and as we see in the transformer secondary coil and cokes it's all one secondary coil which is located only 50% in unipolar magnetic fields 
and so we have a potential difference plus and minus properly distributed 50% 50% in both fields 

and as you said that is a common transformer

 

what most people is missing is how to get more voltage than 12volts out of the primary when it collapses into the secondary. A typical 1-30 stepup transformer ratio with 12volt into the primary will give 360 output voltage. Everyone needs to look into how to get the 12volt to produce a couple thousand volts or more before it collapses into the secondary. There is a way to do this, and it all depends how the primary circuit is build and designed. Study how a fly-back transformer works and you will find the answer.

 

The 25 milliamps is measured going into the cell, not into the primary. The primary input current will be much higher. That being said, it still boils down to watts in watts out. So if we put 12 volts in and 2 amps, we get 24 watts power in. Now if we have 25 milliamps at the cell input, that means we have 960 volts going to the cell, still 24 watts. Then when resonance is achieved, at 2 milliamps that would be @ 12kv at the cell, again still 24 watts. Watts in watts out. 

 

The way I am reading it is this: You are pulsing in say 360 volts to the capacitor, which the diode (600v) can handle easily. 
This voltage can't return due to the diode. So in goes another pulse and we have 720v stored in the capacitor, then on the 3rd pulse its 
1080v etc. I just think the the huge voltages are accomplished inside the capacitor (cell) and not in the vic coil. When the capacitor reaches 
the required voltage (matching the dielectric of the water) the water breaks down. 
The cell is after all an unlimited capacitor only limited by the water itself. And when that limit is reached hey presto! 
I have no idea how to measure the voltage potential in between the plates but that's where I think you will find the high voltages and not 
in the vic coil. 

 

 resonance should start with less impulse and more watts or power in creating HHO gas,and then move slowly with increasing pulse and decreasing power -Now if you hit a high voltage from the start such current will pass through the water without any problems 
when we create HHO My opinion is ,bond breaking is also liberates current and this current will increase with time in cells-not chokes 

 

the purpose of chokes are to limit amps. however, clearly stan called them charging chokes and speaks of a charge pump. a cell is not a charge pump. the inductors are the charge pump.....resonant charge pump...... the cell then receives that charge 

the only way to do that is to charge the transformer, which is how i get the step charge on the scope. 

the chokes are on the same core as the transformer, so they are charged when the transformer is charged 

the only way to see it, is to do it.......you need the setup of meyer, or simular 

 

amps are current, which is electron flow. volts are independent from amps. if you were only using voltage potential.............electron flow would be at a minimum. a voltage potential, would not be consuming anything. like a battery not connected. it has pos and neg ions...........a voltage potential. you can charge that battery with ma. or huge amps. you can hit it with high voltage pulses as well. over charge the battery, and you produce hydrogen

 

not going to get into how to create more voltage on the primary side with 12volts there are more parts on the primary side than just a frequency generator and a transistor. I gave everyone a reference to look into, there is a lot of math involved on the primary side. Either you believe in Stan's words or you don't. He said no electron flow on the secondary side just voltage other than 1-2 m/amps through the cell.

 

Stan  said no electron flow on the secondary side just voltage other than 1-2 m/amps through the CELL MAIN ROLE OF Stans transformer Preventing the flow of electrons AND PHYSICAL thin wire would not withstand FLOW 


But if you fill CELLS with an electrons Magnetic field OF transformer AND HIGH ELECTRICITY WILL PREVENT ENTRY larger amounts of electrons in the WIRES NOW STAY resonance AND magnetic field that pushes electrons FORWARD AND BACK Which are located only in cells 
AND THIS IS WHAT WE ARE LOOKING For , WE NEED ONLY CONFIRMATION OF DATA

 

The reason I started this thread is so many people are using a frequency generator and a transistor to pulse 12volts or what ever voltage into a primary and expecting more voltage out of the secondary than the turn ratio will allow. Stan used an example of a 1-30 ratio transformer. If you put 12volts into that transformer all your ever going to get is 360volts out. Well If you believe in what Stan says, he said the voltages can reach as high as 20000volts. But if you find a way to turn the 12volts into 600volts first you will output 18000volts with a 1-30 ratio. Now the challenge for everyone is to find a way to do it. While maintaining your resonate frequency.

 

STANS TRANSFORMER IS ONLY DEVICE FOR resonance ,And as you have already proven YOU HAVE resonance in THE WATER cell or Capacitor 
Now the resonance WILL resonate that charge in a cell FOREVER FOREVER FOREVER FOREVER FOREVER 
AND BECAUSE OF magnetic fields AND CHOKES ELECTRICITY will not enter into TRANSFORMER Will remain in the cell where AND WILL NEED TO BE 

 

Produce a higher voltage on the primary than 12volts using 12volts. ( look into the design of a fly-back transformer) 
The chokes are part of the turn ratio of the secondary. 

You can not just use a frequency generator and a transistor to pulse the transformer. 
Phasing the transformer is critical to getting it to work.

And we can't put any more than 600 volts from secondary to the chokes/inductors....... 

According to the upper limit of the inline diode. 

Ok C can get up to 500v from a 120v to 12v turned around and pulsed. 
So that's 384% more power than normal. 

ok so vic coil is 500 primary and 3000 secondary. Ratio 1 to 6. 
So if we put 12v in we would expect 72 volts out. 
But working on the pulsed theory we might see 277v or thereabouts. 

So if we double the input voltage to 24v the figure comes out at 554v 

Now that's magically just below the the diodes upper limit. 

Once beyond the diode we still have a step up of 1 to 2 from primary to the inductors. 

Oh goody that gives us 1108v as a straight ratio. Over the 1000v threshold. 

But does the pulsing effect stop at the diode???? if not and we are looking at another  gain of 384% twice........ 

Eh that gives us 2127v or 4254v if its twice. 

So can I hazard a guess that we nee to be putting in 24v

the diode will pass the pulsing. so the chokes will charge as well 
i got over 2k volts onetime with a transformer that was not connected

30gauge wire at 1000 feet has a resistance of 103.2 ohms. 
Don Gabel gave us 2 readings 11.1 ohms and 11.5 ohms. 
That comes out to 107.5 feet and 111.5 feet. Seeing that is a noninductive bifilar wind one would ask where does the voltage come from that feeds the phase lock loop circuitry.  It would come from the no connection wire!

you need to figure out 10 center tap non-inductive feedback coil need to be tuned in. 
Not just one !!! 

""I had the VIC circuit system at my house twice. 
The first time was without the GMS control panel. 
I had to bypass parts of the systems to get the VIC cards to turn on. 
Then once I had them working. 

""I WAS ABLE TO GET THEM LOCKED ONTO RESONANCE. 

But there was never any gas being produced. 
""(this means that the pll and scaning circuits are on the vic card ,and read 
on...''.....''the scanner would lock on to...'' 

When looking at the scope shots of the resonance signals,it looked a lot like what we all 
have seen with our ouw setups. 

The only difference was that the scanner would lock onto the third harmonic of the signal. 
It never locked onto the first or primary one. 
By this third harmonic I mean,it would lock onto a pulse train of three pulses. 

The first pulse would be the largest,the second would a little smaller and the third 
would be the smallest,and then it would keep repeating. 
Now there may still have been something else that needed to be hooked up that I didn't 
have . 

Or there may have been something Stan had removed to keep it from working that we don't 
know about ,because he never published it to prevent anyone from replicating it. 

So that's about all I can say about it. I couldn't get it to work. 
Too much of the system had to be put into a bypass mode,that may have kept it from 
working,or something was still missing that we don't know about. 
Don 

Thinking like a radio wave all voltage a little bit of magnetic and absolutely no current!

MAx Miller Reported  He got zero current and 300 volts across the cell mili ohm meter had no movement.........none

He is  sure there was a mi-nute amount......the point is the feedback would be picking up a very small field

Testing the Original VICS

Used to Find and Lock Resonance

Don "Also was able to test all the VIC driver board and they would all lock on to a resonance once I adjusted the small blue pot on the board. It's a frequency centering pot. It sets up the range of the scan frequency. No gas output at all, it would make the same signal as my own test. An AC sine wave, at a couple hundred volts if my memory serves me right."

Heat Sink & Transistor

VIC

This shows what the signal should look like into and out of the Stan Meyer VIC.

 

quotes from stan meyer " to accomplish the formation of unipolar gated pulse-wave (64a xxx T3 xxx 64n) without experiencing "signal distortion" or "signal degradation" (preventing transformer ringing during signal propagation) as elevated voltage levels ""Switching Diode (55) of Figure (3-22) prevents Bidirectional electron flow (current flow in one direction only) since Blocking - Diode (55) only conducts "current flow" in the direction of schematic-arrow while being placed in-line with VIC Circuit impedance interaction (R1 + Z2 + Z3 .•. Re),

 

as mathematically extrapolated in Circuit Equation (Eq 9) ... Diode (55) being placed between Secondary Pickup Coil (52) and Resonant Charging Choke (56) to act as an electronic switch in open-position during pulse off-time (T2) of Figure (7-8) while preventing electron flow in reverse direction when Inductor (L1) collapsing electromagnetic field (FLl) produces another unipolar pulse wave-form ( 64a - 64b) ... producing unipolar voltage wave-form (64a xxx 64n) during repeated pulse-signal (46a xxx 46n) on-time (Tla xxx TIn) ..

 

. allowing the formation of an gated pulse- frequency pulse-train (64a/64b - T3 - 64a/64b) when pulse off-time (T3) is greater than time-period (T2) ... input-signal (49a xxx 49n) being a Pulse-Train where (T2) pulse offtime (T2) is adjusted to allows Unipolar Pulse-Train (64a xxx T3 xxx 64n) ... outputting Voltage-wave signal (64a xxx 64n) being a pulse-frequency doubler due to Inductance Reactance (FL) of Inductor Coil (56) of Figure (3-22) when collapsing magnetic field (FI) of Figure (7-3b) re-cuts coil-wrap (Ll) during each pulse off-time (T2) ..

 

 

. producing a second unipolar voltage wave-form (64b) during the rise and fall of magnetic field (71), as further illustrated in (620) of Figure (7-1).""Component Interaction promotes Component Reactance during D.C. pulsing operations while allowing variable voltage amplitude (Vo - Va -Vb - Vn) of Figure (7-13) to be attenuated independently of Voltage Pulse frequency""Inductance Reactance not only increases voltage across water-capacitor (ER) beyond applied Voltage Potential (626) of Figure (7-7) but, also, establishes "Impedance Field" (FL) across Inductors"" increases applied voltage amplitude (Vo - Vn),

 

 

doubles input frequency (64a * 64b) when 50% Duty Cycle Pulse (Tl = T2) is inputted, effectuates "Step Charging Effect" ""Inductors (LIIL2) should always be larger than Capacitor (ER) of Figure (7-2) in order to maximize amp restriction to enhance "Voltage Deflection" ""Capacitor (ER) should remain relatively small due to the dielectric value of water ""In terms of thermal explosive energy-yield (gtnt) under dynamic pressure of compression approximately 7.4 (µl) microliter of a liquid-volume of a water droplet per injection cycle is all that ~s required to run the Dune Buggy 1600cc 50hp VW I.C. engine at 65 m.p.h. on the open road; whereas, a typical 325 hp diesel I.C. truck-engine would require about 48.1 (µl) microliters of a water droplet per injection cycle to accomplish the same open road performance. (see WFC Water vs Gasoline Energy Content Equations (memo WFC 429)."

 

 

Vic Style 1 Core

VIC

Ferrite Core

 

The vic transformer  Core Permability

1200 perm is right on the money

1600 perm is on the money with a piece of tape on one side to make a gap.

2000 perm however is closer to the frequency of 5khz

 

Inductor 

i would say the inductor needs to be 1 H for 10 cells in series

Power Supply Frequency Generator 

 of the VIC CIRCUITS

 

Can anyone explain to me what the unipolar magnetic field coupling is exactly?

my theory is its a circular constant motion of energy 

 

Not sure why Stan uses unipolar in the description, but the magnetic coupling is how a transformer works. A pulse is made in the primary coil when a voltage is applied. When that pulse ends, it is transferred through the core material as a magnetic flux, and picked up by the secondary coil. There isn't any physical connection between the two coils. So power is transferred through magnetic coupling. Only a pulse can passed through, it has to turn on and off to work. If you just apply a straight voltage to the primary , it won't pass through the core until it turns off. 

 

They are time constants involve in pulsing the primary Di/Dt that is his the reason he shows 5 pulses for 5 time constants. Look into this you will find your answer.

 

yes ronnie knows i was messing around. you will not find any unipolar pulse in the test books............ it is the way the pulse is input into the coil and back out again.............there are many educated people who have said meyer was a scam, because there is no such thing as a unipolar pulse. but there are several on this forum that have generated them....not just Max

Home Builder Replications

VIC

VIC Driving Circuits 

this is the driver for the vic in that board, it is there end  also is a variable voltage driver

obviously we can see a voltage changer, and the pulse into the pnp transistor would be the inverse of the pulse into the npn transistor at the end

Amplitude Control from the VIC 

"While working out the routing of the various circuits in the VIC card,I have found that there are four op amps on the one end of the board.

 

Three of these op amps are shown in the schematic,and the fourth one is not.The very first one of the op amps, the one closest to the tabs that plug the board in,is not in the schematic,and gets a signal from some source,and the second op amp gets a signal from the GMS control panel circuit Analog Voltage Generator.

 

Now these two signals come into the coil pack through the nine pin connector and pass into this board.What I have found is that the first two op amps are wired in parrallel and go into the third one.

 

There seems to be two different signals coming into these first two op amps,and are being joined. Ok so my question to you all is, what other signal could be coming into these op amps?

 

What purpose would it be to join two signals together through op

Those op amps go to the voltage amplitude control circuit.

Tesla Vs Meyers

Look Very Close at the Details.

This is really just a charge pump, it is Tesla 101, if you take out the spark gap And secondary side of a tesla coil schematic, this is What you get. The entire secondary builds over time, (provided You have a high insulative barrier between The secondary and the "outside world" once that is breached, Through an arc to the core, etc, you have reached your max. Notice how thick meyers insulation was between his coils and the core, How they were isolated etc.

Stan Meyer-VIC Replication parts

 

-4 ea pieces UY1658 MnZn ferrite core from Ebay, Amazon, Aliexpress

-4 ea pieces 1613-0 bobbins from cosmocorp

-3,000ft 29 AWG heavy magnet wire from Temco

 

-3/8 or 1/2 plastic washers

 

-MUR1560 diode -200 or 400 grit sandpaper

 

You'll also need a means to clamp the cores together, I mounted mine in an aluminum enclosure with aluminum L channel, screws,

and delrin bushings against the cores.

 

For the connections I used a terminal block as well as delrin bushings, insulated BNC connectors, and SMA coax connectors.

 

*The ferrite bead pickup coil will not give you accurate voltage readings... but it does show you what your waveform looks like and makes finding resonance much easier.

I'm a paragraph. Click here to add your own text and edit me. It's easy.

It is Crazy we have to have 3 and 4 and 5 back ups of sites docs and videos  it is a constant effort to keep this here

save all that you see and re  upload  after all the only reason you can see this is we have done that  consider supporting us 

JOIN AS A SUPPORTER or Donate HERE   https://www.patreon.com/securesupplies

 

PAYPAL LINK Donation https://www.paypal.me/SecureSupplyUSALLC/25

My Paypal     daniel_donatelli@yahoo.com

 

MY BITCOIN ADDRESS: Bitcoin Donation

BCH

qzskj2v6sznjtwa8wpuyhse4hwh3e6lhrsg8qvtl56

 

BTC

1BiTfFLg4c3rtFzBHf3joHNki5yrjtZ4Gj

 

Contact me at email:

danieldonatelli1@gmail.com

 

Books Can be Ordered here

  https://danieldonatelli.wixsite.com/hydrogen-power-gas/company-books

About Us

Secure Supplies Media Group is

an international collective of Hot Rodders photographers, writers & drivers with a shared passion for promoting the world's most exciting

Hydrogen car culture stories.

Contact Us

We're always very interested to hear your own stories as well as to receive your feedback.

Please New Members first but if you don't find what you are looking for then you are welcome to contact us via email, thank you.

Secure Supplies  Social

 Facebook- @SecureSupplies

 Twitter      @SecureSupplies

 Instagram - SecureSupplies​

 Pinterest   - Secure.Supplies

 Minds         - SecureSupplies 

 Youtube       - SecureSupplies

Tip Us Please

$10  $25    $50   $100   $250  $500

Team Secure

Editor in Chief: Daniel Donatelli 
Senior Editor: Simone White
Editor at Large: Johny Case
Commercial Director: Willem Coetzee
Community Manager: Ryan
Butters
Technical Editor: Jason Nash
Concept Artist:  Samuel Hill
Senior Contributors:  Jacky Bright
Contributors:  Sally Smith, Joanne Livey, Bruce Smith.

Event Partners

Untitled.png

Automotive Partners

Back to Main Site 

www.securesupplyusa.com

logo.jpg

Merchandise Partners

Manufacturing  Partners

Manufacturing.png

Wechat

Whatsapp

Line

Skype

Secure Supplies Energy Power Gas Magazine ™

All Rights Reserved Worldwide. Copyright © 2012 Secure Supplies Limited Daniel Donatelli © 2009 

TRADEMARKS BELONG TO THEIR RESPECTIVE OWNERS. ALL RIGHTS RESERVED

 No duplication is permitted of this site graphically or
conceptually unless requested and approved in writing.

TERMS OF SERVICE // PRIVACY & COOKIE POLICY // LEGAL NOTICES // ADVERTISING OPPORTUNITIES

Work with us Employment